Shop
This is where you can browse products in this store.
All Brands
All Categories
- NGI (53)
- Analyzer IM7580 (1)
- Color, Light and Display Test Solution (18)
- Data Logger (2)
- DC Electronic Load (3)
- Electrical Test Solution (54)
- Electronics Test Solution (213)
- Environment Test Solution (34)
- ETAC (14)
- High Precision Multi Channel Programmable DC Power Supply (1)
- High Precision Source Measure Unit (1)
- Hioki (5)
- Kanomax (7)
- Konica Minolta (16)
- Material Property Test Solution (12)
- MEMORY HiCORDER (3)
- Particle Counters (1)
- Probes (3)
- Rigol (180)
- Yasuda Seiki (14)
-
- Color, Light and Display Test Solution, Konica Minolta, Spectrophotometer
Konica Minolta Spectrophotometer CM-25cG
- Spectrophotometer CM-25cG Model CM-25cG Colour Gloss Illumination/viewing system 45°c:0° method (45° circumferential illumination, 0° vertical viewing) CIE No.15, ISO 7724/1, ASTM E179, DIN 5033-7, JIS Z 8722 compliant 60° ISO 2813, ISO 7668, ASTM D523, ASTM D2457, DIN 67530, JIS Z8741, JIS K5600 compliant optical system Detector Dual 40-element silicon photodiode arrays Silicon photo diode Spectral separation device Planar diffraction…
- Read more
-
- Color, Light and Display Test Solution, Konica Minolta, Spectrophotometer
Konica Minolta Spectrophotometer CM-3630
- Spectrophotometer CM-3630 Model CM-3630 Illumination / observation system Reflectance:d/0 (diffused illumination, 0-degree viewing) Conforms to ISO 2469, JIS P8148, DIN 53145-1 and DIN 53145-2 standards. Light-receiving element Silicon photodiode array (dual 40 elements) Spectral separation device Diffraction grating Wavelength range 360nm to 740nm Wavelength pitch 10 nm Half bandwidth Approx. 10nm Reflectance range 0 to 200%; resolution: 0.01% Light source…
- Read more
-
- Color, Light and Display Test Solution, Konica Minolta, Spectrophotometer
Konica Minolta Spectrophotometer CM-36d
- Spectrophotometer CM-36d Color Illumination/ Viewing System Reflectance: di:8°, de:8° (diffused illumination, 8° viewing), SCI (Specular Component Included) / SCE (Specular Component Excluded) switchable. Conforms to CIE No.15, lSO7724/1, ASTM E1164, DIN 5033 Teil7, and JIS Z 8722 condition c standards Integrating Sphere Size Ø152 mm (6 inches) Detector Dual 40-element silicon photodiode arrays Spectral Separation Device Diffraction grating Wavelength Range…
- Read more
-
- Color, Light and Display Test Solution, Konica Minolta, Spectrophotometer
Konica Minolta Spectrophotometer CM-36dGV
- Spectrophotometer CM-36dGV Color Illumination/ Viewing System Reflectance: di:8°, de:8° (diffused illumination, 8° viewing), SCI (Specular Component Included) / SCE (Specular Component Excluded) switchable. Conforms to CIE No.15, lSO7724/1, ASTM E1164, DIN 5033 Teil7, and JIS Z 8722 condition c standards Transmittance: di:0°, de:0° (diffused illumination, 0° viewing) Conforms to CIE No.15, ASTM E1164, DIN 5033 Teil7, and JIS Z 8722…
- Read more
-
- Environment Test Solution, ETAC, Walk-in chamber, Walk-in chamber
Large Constant Temperature (Constant Humidity) Room COLONIA E series Walk-in Chamber
- CH111P-E CH121P-E CH311P-E CH321P-E CH331P-E cooling machine air-cooled air-cooled air-cooled air-cooled water cooling water cooling water cooling water cooling water cooling Test chamber dimensions (W x H x D mm) 1670×2200×1670 3470×2200×1670 1670×2200×1670 3470×2200×1670 1670×2200×1670 3470×2200×1670 1670×2200×1670 3470×2200×1670 3470×2200×2570 Contents ( m3 ) 6.1 12.7 6.1 12.7 6.1 12.7 6.1 12.7 19.6 Floor area ( m2 ) 2.79 5.79 2.79 5.79 2.79 5.79 2.79…
- Read more
-
- Electronics Test Solution
Lightning Surge Simulator (LSS) Lightning Surge Simulator LSS-720B2
- Parameter LSS-720B Voltage surge Output waveform 1.2/50μs Max. output voltage 20 kV Polarity Positve or negative Output impedance 6 Ω ± 10 % Built-in load resistance 50 Ω ± 10% (Current limit resistance 100 Ω) Short current at max. output 3300 A Current surge Output waveform 8 / 20μs Max. output current 4000 A Polarity Positive or negative Output impedance…
- Read more
-
- Environment Test Solution, ETAC, Low Temperature & Humidity Test Chamber, Low Temperature & Humidity Test Chamber
Low Temperature and Humidity Chamber HIFLEX NEO-E Series
- Model FX412N-E FX422N-E FX432N-E FX711N-E FX721N-E FX721N-E FX631N-E Inner dimensions (W x H x D mm) 600×750×600 700×950×700 1000×1000×800 600×750×600 700×950×700 1000×1000×800 1000×1000×800 Contents (L) 270 465 800 270 465 800 800 Temperature Range 1 -40℃~+100℃ [+150℃] -40℃~+100℃ [+150℃] -40℃~+100℃ [+150℃] -70℃~+100℃ [+150℃] -70℃~+100℃ [+150℃] -70℃~+100℃ [+150℃] -60℃~+100℃ [+150℃] Humidity Range 20-98%RH 20-98%RH 20-98%RH 20-98%RH 20-98%RH 20-98%RH 20-98%RH
- Read more
-
- Environment Test Solution, ETAC, Low Temperature & Humidity Test Chamber, Low Temperature & Humidity Test Chamber
Low Temperature Constant Temperature and Humidity Chamber HIFLEX SC Series
- Low temperature constant temperature and humidity chamber Model FX310 FX320 FX330 Inner dimensions (W x H x D mm) 600×750×600 700×950×700 1000×1000×800 Contents (L) 270 465 800 Temperature range -30℃~+100℃ [+150℃] -30℃~+100℃ [+150℃] -30℃~+100℃ [+150℃] Humidity Range 20%RH to 98%RH 20%RH to 98%RH 20%RH to 98%RH Low temperature and humidity chamber Model FL310 FL320 FL330 Inner dimensions (W x H…
- Read more
-
- Out of Stock
- Material Property Test Solution, Melt Flow Index (MFI) Tester, Yasuda Seiki
Melt Flow Index Tester (Full Automatic)
- Reference Standards JIS K 6719-1/2, K 6921-2, K 6922-2, K 6923-1, K 6924-1, K 6926-2, K 7210-1, ISO 1133-1, ASTM D1238 Number of Samples 12, 24 or 50 samples per test cycle (3 kinds) Die φ2.095 ± 0.005 mm, L8.000 ± 0.025 mm Piston Head Diameter φ9.474 ± 0.007 mm, Head Length L6.35 ± 0.10 mm Cylinder Inner φ9.550 ±…
- Read more
-
-
- Hioki, MEMORY HiCORDER
MEMORY HiCORDER MR8848
- Measurement functions Memory function (waveform recording), Recorder function (peak/trough recording), X-Y Recorder function, FFT function Max. number of channels 16 ch analog + 16 ch logic 32 ch analog + 16 ch logic (when U8975 or U8978 × 8 is attached) 10 ch analog + 64 ch logic (when main unit logic + Logic Unit 8973 × 3 is attached)…
- Read more
-
- Hioki, MEMORY HiCORDER
MEMORY HiCORDER MR8870
- Number of channels 2 analog channels + 4 logic channels (standard) Note: Isolated analog channels, isolated input and frame, logic has common GND Measurement ranges 10 mV to 50 V/div (10 div full-scale), 12 ranges, Resolution: 1/100 of range Max. rated voltage Between terminals: 400 VDC, Between terminal to earth: 300 VAC, DC CAT II Frequency characteristics DC to 50…
- Read more
-
- Hioki, MEMORY HiCORDER
MEMORY HiCORDER MR8880
- Number of channels 4 analog channels + 8 logic channels (standard) Note: Isolated analog channels, isolated input and frame, logic has common GND Measurement ranges (10 div full-scale) 4 channels of voltage measurement; mode switchable between instantaneous waveform or RMS value, 10 mV to 100 V/div, 13 ranges, resolution: 1/640 of range RMS value mode: 30 Hz to 10 kHz,…
- Read more
































