Kanomax
All Brands
All Categories
- NGI (56)
- Analyzer IM7580 (1)
- Color, Light and Display Test Solution (20)
- Data Logger (1)
- DC Electronic Load (3)
- Electrical Test Solution (56)
- Electronics Test Solution (210)
- Environment Test Solution (37)
- ETAC (14)
- GW Instek (7)
- High Precision Multi Channel Programmable DC Power Supply (1)
- High Precision Source Measure Unit (1)
- Hioki (5)
- Kanomax (7)
- Konica Minolta (18)
- LCR Meter (1)
- Leakage Current Tester (1)
- Material Property Test Solution (18)
- MEMORY HiCORDER (3)
- Metrology Analytical Test Solution (5)
- Multi-Channel Hipot Tester (1)
- Particle Counters (1)
- PSU-Series Programmable Switching D.C. Power Supply (1)
- PSW-Series Programmable Switching D.C. Power Supply (1)
- Rigol (181)
- Shimadzu (5)
- Tektronix (2)
- Yasuda Seiki (19)
-
- Cleanroom Monitoring, Kanomax
Anemomaster Professional HVAC Anemometer – Model 6036
- Air Velocity Range 2 to 6000 FPM (0.01 to 30.0m/s) Resolution 1 FPM (0.01 m/s) Accuracy +/- 3.0% of READING or 0.015 m/s Temperature Range -4 to 158°F (-20 to 70°C) Resolution 1°F (0.1°C) Accuracy +/- 1°F (+/- 0.5 °C) Range -5 to 5 kPa Differential Pressure Range -5 to 5 kPa Resolution 0.01 m/s 0.1 m/s Accuracy ±3% of…
- Read more
-
- Cleanroom Monitoring, Kanomax
Cleanroom Monitoring System – Model CRMS
- Main Unit Specifications Measuring Particle Size 3718-A: 0.3µm and 0.5µm; 3719-A: 0.5µm and 5.0µm Counting Efficiency 50% +/- 20% at smallest particle channel Coincidental Loss Less than 10% at 500,000 particles/cf Zero Count Less than 1 count / 5 minutes General Specifications Flow Rate 1.0 cfm (28.3 l/min) Light Source Laser diode Interfaces RS485 (Modbus capability); Analog output (4-20mA) Enclosure…
- Read more
-
- Anemometer, Kanomax
Climomaster Anemometer – 6501 Series
- Main Unit Specifications Differential Pressure Range -5 to 5 kPa Resolution 0.01 kPa Accuracy ±3% of READING or ±0.01 kPa whichever is greater General Specifications Analog Output DC 0 to 1 V Interface USB / Printer Datalogging Stores up to 20000 measurement data Power Supply 6 × AA Batteries or AC Adapter (AC 100 to 240 V , 50/60 Hz)…
- Read more
-
- Kanomax, Particle Counters
Handheld Particle Counters – Models 3888 and 3889
- Main Unit Specifications Product Handheld Particle Counter Model 3888 3889 Particle Measurement Sizes 3 channels (0.3, 0.5, 5.0μm) 6 channels (0.3, 0.5, 1.0, 3.0, 5.0, 10.0μm) Flow Rate 0.1CFM (2.83L/min) Accuracy: ±5% (Compliant with JIS B9921 and ISO21501-4) Maximum Measurable Concentration 10% for 2,000,000 particles/CF (compliant with JIS B9921 and ISO21501-4) Counting Efficiency 50±20% (for PSL particles near the minimum…
- Read more
-
- Air Quality Test Solution, Anemometer, Anemometer, Kanomax
Multi-Channel Anemometer – Model 1580
- Model 1580-00 Number of Channels Up to 12 channels Communication Function Between PC USB Micro-B Between Probe Serial communication (standard cable) Between Probe Serial communication (connector) Power Supply DC12 to 24V (Select either one of 3 options below) 1) Connection with other unit, 2) AC adaptor (90W), 3) DC power cable Power Consumption Up to 50W Operating Environment 5~40℃, 0~85%…
- Read more
-
- Air Quality Test Solution, Anemometer, Anemometer, Kanomax
Multi-Channel Anemometer PRO – Model 1590
- Product Multi-Channel Anemomaster PRO Main Unit Model 1590-00 Display, Operation 7-inch color LCD with touch panel Communication Function Data USB Type-A: For USB memory Remote Measurement Modbus (Ethernet, USB Serial) Between Units RS485 (Standard cable) Recording Media Medium Built-in memory Format CSV format Recording Capacity 8GB (One hub unit can measure 1000 sampling times, about 24500 times). External Trigger Input…
- Read more
-
- Kanomax, Portable particle Counter
Portable Particle Counters – 3900 Series
- Model 3905 3910 3920 Light Source Laser diode Measuring Particle Size 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 (μm) 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 (μm) Flow Rate 1.0 CFM (28.3 LPM) 1.77 CFM (50 LPM) 3.5 CFM (100 LPM) Counting Efficiency 50±20% at 0.3μm 50±20% at 0.5μm Concentration Limit 500,000 particles/ft³ at 10% coincidence loss 300,000 particles/ft³ at 10% coincidence…
- Read more



























