• Data logger expandable to 330 ch Quick View
    • Data logger expandable to 330 ch Quick View
    • ,
    • Data logger expandable to 330 ch

    • Max. number of connectable modules 4 plug-in modules + 7 wireless modules Connectable modules (Plug-in modules) See [Options] > [Plug-in modules] Connectable modules (Wireless modules) See [Options] > [Wireless modules] No. of measurement channels Up to 120 ch with plug-in modules, up to 330 ch with plug-in modules and wireless modules (U8555 and LR8535 can input up to 500 channels…
    • Read more
  • IMPEDANCE ANALYZER IM7587 Quick View
    • IMPEDANCE ANALYZER IM7587 Quick View
    • ,
    • IMPEDANCE ANALYZER IM7587

    • Measurement modes LCR mode, Analyzer mode (sweeps with measurement frequency and measurement level), Continuous measurement mode Measurement parameters Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q Measurable range 100 mΩ to 5 kΩ Display range Z: 0.00 m to 9.99999 GΩ / Rs, Rp, X: ± (0.00 m to 9.99999 GΩ) Ls,…
    • Read more
  • MEMORY HiCORDER MR8848 Quick View
    • MEMORY HiCORDER MR8848 Quick View
    • ,
    • MEMORY HiCORDER MR8848

    • Measurement functions Memory function (waveform recording), Recorder function (peak/trough recording), X-Y Recorder function, FFT function Max. number of channels 16 ch analog + 16 ch logic 32 ch analog + 16 ch logic (when U8975 or U8978 × 8 is attached) 10 ch analog + 64 ch logic (when main unit logic + Logic Unit 8973 × 3 is attached)…
    • Read more
  • MEMORY HiCORDER MR8870 Quick View
    • MEMORY HiCORDER MR8870 Quick View
    • ,
    • MEMORY HiCORDER MR8870

    • Number of channels 2 analog channels + 4 logic channels (standard) Note: Isolated analog channels, isolated input and frame, logic has common GND Measurement ranges 10 mV to 50 V/div (10 div full-scale), 12 ranges, Resolution: 1/100 of range Max. rated voltage Between terminals: 400 VDC, Between terminal to earth: 300 VAC, DC CAT II Frequency characteristics DC to 50…
    • Read more
  • MEMORY HiCORDER MR8880 Quick View
    • MEMORY HiCORDER MR8880 Quick View
    • ,
    • MEMORY HiCORDER MR8880

    • Number of channels 4 analog channels + 8 logic channels (standard) Note: Isolated analog channels, isolated input and frame, logic has common GND Measurement ranges (10 div full-scale) 4 channels of voltage measurement; mode switchable between instantaneous waveform or RMS value, 10 mV to 100 V/div, 13 ranges, resolution: 1/640 of range RMS value mode: 30 Hz to 10 kHz,…
    • Read more