Spectrophotometer CM-36dGV

Spectrophotometer CM-36dGV

Color Illumination/ Viewing System Reflectance: 

di:8°, de:8° (diffused illumination, 8° viewing), SCI (Specular Component Included) / SCE (Specular Component Excluded) switchable.

Conforms to CIE No.15, lSO7724/1, ASTM E1164, DIN 5033 Teil7, and JIS Z 8722 condition c standards

Transmittance: 

di:0°, de:0° (diffused illumination, 0° viewing)

Conforms to CIE No.15, ASTM E1164, DIN 5033 Teil7, and JIS Z 8722 condition g standards

Integrating Sphere Size Ø152 mm (6 inches)
Detector Dual 40-element silicon photodiode arrays
Spectral Separation Device Diffraction grating
Wavelength Range 360 to 740 nm
Wavelength Pitch 10 nm
Half Bandwidth approx. 10 nm
Reflectance 

Range

0 to 200%
Resolution: 0.01%
Light Source 3 Pulsed xenon lamps (2 with UV cut filters)
Illumination / Measurement Area LAV: Ø30.0 mm / Ø25.4 mm 

LMAV: Ø20.0 mm / Ø16.0 mm

MAV: Ø11.0 mm / Ø8.0 mm

SAV: Ø7.0 mm / Ø4.0 mm

Trans: Ø24.0 mm / Ø17.0 mm

Repeatability Colorimetric values: Standard deviation within ΔE*ab 0.02 

Spectral reflectance: Standard deviation within 0.1%

(When a white calibration plate is measured 30 times at 10-second intervals after white calibration)

Inter-Instrument Agreement Within ΔE*ab 0.12 

(Based on average for 12 BCRA Series II color tiles; LAV/SCI. Compared to values measured with master body under Konica Minolta standard measurement conditions)

UV Setting 100% / 0% / Adjusted 

Instantaneous numerical adjustment of UV with no mechanical filter movement required*1; 400 nm and 420 nm UV cutoff filters

Gloss Measurement Angle 60°
Light Source White LED
Detector Silicon photodiode
Measurement Range 0 to 200 GU
Resolution: 0.01 GU
Measurement Area MAV (LAV/LMAV/MAV color measurement area): 

Ø10.0 x 8.0 mm ellipse

SAV (SAV color measurement): 

Ø3.0 mm

Repeatability 0 to 10 GU: within 0.1 GU 

10 to 100 GU: within 0.2 GU

100 to 200 GU: 0.2%

(When measured 30 times at 10-second intervals)

Inter-Instrument Agreement 0 to 10 GU: ±0.2 GU 

10 to 100 GU: ±0.5 GU

(MAV. Compared to values measured with master body under Konica Minolta standard conditions)

Geometry JIS Z 8741 (MAV), JIS K 5600, ISO 2813, ISO 7668 (MAV), ASTM D523-08, ASTM D2457-13, and DIN 67530
Measurement Time Approx. 3.5 second (SCI+SCE measurement) 

Approx. 4 second (SCI+SCE+Gloss measurement)

Approx. 2.5 second (Transmittance)

Approx. 3 second (UV-cut/UV-adjusted; SCI or SCE)

Minimum Interval Between Measurements Approx. 4 second (SCI+SCE measurement) 

Approx. 4.5 second (SCI+SCE+Gloss measurement)

Approx. 3 second (Transmittance)

Approx. 4 second (UV-cut/UV-adjusted; SCI or SCE)

Sample Viewer Function Using internal camera 

(Image viewable/copiable using optional software such as SpectraMagic NX software Ver. 3.2 or later)

Internal Performance Check*2 WAA (Wavelength Analysis & Adjustment) Technology
Interface USB 2.0
Target Mask Auto Detection Yes
Power Dedicated AC adapter
Operating temperature / humidity range 13 to 33°C, Relative humidity: 80% or less (at 35°C) with no condensation
Storage temperature / humidity range 0 to 40°C, Relative humidity: 80% or less (at 35°C) with no condensation
Size (W x H x D)  Approx. 300 x 677 x 315 mm
Weight  Approx. 14.0 kg

Description

Spectrophotometer CM-36dGV

The Konica Minolta Spectrophotometer CM-36dGV is a highly precise and reliable benchtop color measuring instrument designed for digital color measurement and management that offers advanced functionality to meet today’s color measurement needs. The successor of the Spectrophotometer CM-3610A, this color measurement instrument is equipped to measure color in reflectance or transmittance mode and features a 60° gloss sensor (ISO 2813 compliant) that enables simultaneous color and gloss measurement, thereby improving work efficiency. 

The Spectrophotometer CM-36dGV comes with the patented Numerical UV Control (NUVC) that facilitates accurate and simple UV adjustments while measuring samples containing optical brighteners (OBA) such as pulp, paper, and textiles. It offers a tight inter-instrument agreement (IIA) of ΔE*ab< 0.12 and repeatability of σ∆E*ab < 0.02, ensuring that the color measurement and data are communicated consistently within the supply chain from suppliers to finished product makers. 

This innovative benchtop spectrophotometer stands out for its user-friendly design. Its vertical orientation ensures easy handling of samples such as cloth and paper. The Spectrophotometer CM-36dGV comes equipped with a viewing function that uses an integrated camera for accurate and easy positioning of samples. It also features an easy-to-read status panel with a measuring button that displays the measurement status and condition settings to minimize operator error and improve work efficiency. The Spectrophotometer CM-36dGV offers four different aperture sizes (Ø 4.0 mm, 8.0 mm, 16.0 mm, and 25.4 mm), catering to a variety of measurement needs. 

The Spectrophotometer CM-36dGV goes beyond conventional color measurement with its innovative Wavelength Analysis & Adjustment (WAA) function (optional). Through the WAA function, users can analyze and adjust any wavelength shift during each calibration, ensuring that the instrument and its measurement remain accurate and reliable over time.

Reviews

There are no reviews yet.

Be the first to review “Spectrophotometer CM-36dGV”

Your email address will not be published. Required fields are marked *