Fast Transient Burst Simulator(FNS) Fast transient / burst simulator FNS-AX4-A20 / B63

Parameter Specification / Function
Output voltage 200 to 5000 V 10 V Step
Polarity Positive or negative, polarity alternation possible per burst
Repetition frequency 0.1 kHz to 2000 kHz
0.1 kHz to 1 kHz / 0.01 kHz step Tolerance ± 5%, 1.0 kHz to 10 kHz / 0.1 kHz step Tolerance ± 5%
10 kHz to 100 kHz / 1 kHz step Tolerance ± 5%, 100 kHz to 1000 kHz / 10 kHz step Tolerance ± 5%
1000 kHz to 2000 kHz / 100 kHz step Tolerance ± 10%,  (Limitation per voltage levels when continuous output)
Number of pulses 1 to 1000 at a step of 1 pulse , Setting limit: 1 pulse per ms in a burst (repetition frequency 1 kHz or more)
Burst duration Formula for Burst duration = Pulse number / Repetition Frequency
Scope of manually setting value for burst duration: 0.01 to 999 ms
Burst period 10 to 1000ms ± 10% 10ms steps   (500ms or more for polarity alternate mode)
Polarity alternate function Output polarity alternated between positive and negative at each burst period
Setting condition: the burst period is 500ms or more and the burst pause period [ (burst period) – (burst duration)] is 100ms or more
Maximum test time: 10 minutes
Continuous Pulse output Up to 1000 V -10 kHz or less, to 2000 V -4 kHz or less, to 5000 V -1 kHz or less. Maximum test time for each case: 10 min
Frequency modulation Frequency is shifted continuously between set frequency and approximately -10% from the set frequency. The modulating wave is triangular wave of approximately 20Hz
External trigger External trigger input invokes 1 burst output in synchronization with the trigger input. Trigger specification: Hi (+ 5V) → Lo (0 V) triggers one burst period.
Pulse waveform (at 50 Ω load) Pulse peak voltage: (set voltage / 2) ± 10% Rise time: 5 ns ± 30% Pulse width: 50 ns ± 30%
Pulse waveform (at 1 kΩ load) Pulse peak voltage: (set voltage x 0.95) ± 20% Rise time: 5 ns ± 30% Pulse width: 35 to 150 ns
DC blocking capacitor 10nF ± 20%

Description

It is compact and equipped with new functions to make EMC testing easier.

It is a tester that evaluates the resistance of electronic devices by simulating high-frequency noise that rises quickly due to discharge between contacts of switching devices and arc discharge generated from electronic motors.

  • IEC 61000-4-4 Ed.3 standard compliance.
  • Pre-check function equipped, making. inspection before testing easier.
  • Normal mode test support. for testing for real field troubles. (option)
  • Utilize an outlet box that simplifies EUT connection. (option)
  • Compared with conventional products, the size has become compact. (Approximately 67% by volume)
  • Easy to understand Panel display reduces mistakes in connecting power cables.
  • Windows compatible software control. (option)
  • Next calibration date notification. (Windows software only)
  • LCD screen with multi-language support and enhanced operability.
  • Maximum output voltage of 5 kV and maximum pulse frequency of 2 MHz allowing to test above the standard test level.
  • CDN capacity is increased to single phase type AC 240 V 20 A, single and three phase type to AC 600 V 63 A, supporting a wider range of EUTs.
  • Large capacity CDN (100 A or 150 A) option available for Injection test on various EUTs.
  • Using coupling clamps and EMS probe kit, allows to test signal lines and evaluate noise immunity on PCBs. (option)

Reviews

There are no reviews yet.

Be the first to review “Fast Transient Burst Simulator(FNS) Fast transient / burst simulator FNS-AX4-A20 / B63”

Your email address will not be published. Required fields are marked *