| Illumination / observation system |
Reflectance:
di:8°, de:8° (diffuse illumination: 8° viewing)
SCI (specular component included)/SCE (specular component excluded) switchable
Conforms to CIE No. 15, ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 (Condition c)
Transmittance:
di:0°, de:0° (diffuse illumination: 0° viewing) |
| Integrating Sphere Size |
Ø 152 mm |
| Detector |
Dual 40-element silicon photodiode arrays |
| Spectral separation device |
Planar diffraction grating |
| Wavelength range |
360nm to 740nm |
| Wavelength pitch |
10 nm |
| Half bandwidth |
Approx. 10nm |
| Measurement range |
0 to 175 % (Reflectance or transmittance); Output/display resolution: 0.01% |
| Light source |
Pulsed xenon lamp |
| Measurement time |
Approx. 1 s (to data display/output); Minimum measurement interval: Approx. 3 s |
| Measurement/illumination area |
Reflectance:
Changeable by changing mask and settings. LAV: Ø 30 mm/ Ø 36 mm; MAV (optional): Ø 8 mm/ Ø 11 mm; SAV (optional): Ø 3 mm/ Ø 6 mm
Transmittance:
Ø 26 mm |
| Repeatability |
Spectral reflectance: Standard deviation within 0.1% (400 nm to 740 nm)
Chromaticity value: Standard deviation within ΔE*ab 0.04 * When a white calibration plate is measured 30 times at 10-second intervals after white calibration |
| Inter-Instrument Agreement |
Within ΔE*ab 0.15 (Typical) (LAV/SCI)
(Based on 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard conditions) |
| Transmittance chamber |
No sides (unlimited sample length); Depth (maximum sample thickness): 60 mm
Sample holders (optional) for holding sheet samples or containers of liquid samples can be installed/removed |
| Display |
5.7-inch TFT color LCD |
| Display languages |
English, Japanese, German, French, Italian, Spanish, Simplified Chinese, Portuguese |
| Operating temperature/humidity range |
13 to 33°C, relative humidity 80% or less with no condensation |
| White/100% calibration |
Automatic white (reflectance)/100% (transmittance) calibration using internal white calibration plate
(Not applicable to 100% calibration when using cells for transmittance measurements of liquids.) |
| Interfaces |
USB 1.1 (Connection to PC; USB memory stick); RS-232C standard (Connection to serial printer) |
| Observer |
2° Standard Observer or 10° Standard Observer |
| Illuminant |
A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 (simultaneous evaluation with two light sources possible) |
| Displayed data |
Spectral values/graph (reflectance, transmittance, absorbance), colorimetric values/graph, color-difference values/graph, pass/fail judgment, pseudo color, color assessment |
| Color space |
L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color differences in these spaces (except for Munsell) |
| Index |
Reflectance:
MI; WI (ASTM E 313-73, ASTM E 313-96); YI (ASTM E 313-73, ASTM E 313-96, ASTM D 1925);
ISO Brightness; B (ASTM E 313-73)
Transmittance:
Gardner; Iodine Color Number; Hazen/APHA; European Pharmacopoeia; US Pharmacopeia |
| User index |
User-defined index |
| Color-difference equation |
ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00 (CIE 2000), ΔE (Hunter), CMC (l: c) |
| Pass/fail judgment |
Tolerances can be set to colorimetric values (except Munsell), color-difference values, or reflectance index values |
| Storable data |
Measurement data: 4,000 measurements; Target color data: 1,000 measurements |
| USB memory stick* storage |
Storage of measurement data and target color data. Storage/reading of measurement condition settings
* Security-enabled USB memory sticks cannot be used. |
| Power |
AC 100 to 240 V, 50/60 Hz (using exclusive AC adapter) |
| Size |
Slide cover closed: 385 (W) × 192 (H) × 261 (D) mm
Slide cover open: 475 (W) × 192 (H) × 261 (D) mm |
| Weight |
Approx. 5.8 kg |
| Operating temperature/humidity range |
13 to 33°C, relative humidity 80 % or less (at 35°C) with no condensation |
| Storage temperature/ humidity range |
0 to 40°C, relative humidity 80 % or less (at 35°C) with no condensation |